660 - 1680 Watts CPB1K/1K5 Series
* * * * * * * Universal PFC Input Low Profile (61 mm)
xppower.com
Wide Output Voltage Adjustment Remote On/Off Power Good Signal Remote Sense Peak Current Available
Specification
Input
Input Voltage Input Frequency Input Current Inrush Current Power Factor Earth Leakage Current * * * * * * 85-264 VAC (120-370 VDC) 47-63 Hz 19 A at 115 VAC 40 A at 230 VAC 0.98/0.95 at 115/230 VAC 1.5 mA max at 230 VAC/60Hz
General
Efficiency Isolation * See tables * 3000 VAC Input to Output 2000 VAC Input to Ground 500 VAC Output to Ground * 130 kHz PFC, 200 kHz PWM
Switching Frequency
Environmental
Operating Temperature * -20 C to +70 C, derate linearly from +50 C to 50% at +70 C Relative Humidity * 20-90% non-condensing Storage Temperature * -20 C to +75 C Shock * 20 G 11 ms, once each x, y and z axis Vibration * 2 G, 10 Hz to 55 kHz, 3 min periods for 60 min along each x, y and z axis
Output
Output Voltage Output Voltage Trim Minimum Load Start Up Time Hold Up Time Drift Line Regulation Load Regulation Ripple & Noise Overvoltage Protection Overtemperature Protection Overload Protection * * * * * * * * * * * See tables See tables No minimum load required 400 ms typical at 230 VAC, 100% load 20 ms typical at 100% load 0.4% max 0.5% max 1.0% max 0-100% load 1.0% pk-pk, 20MHz BW 110-130% Vnom, recycle input to reset Operates in the event of fan failure or if the operating temperature / derating criteria is exceeded * Operates at 105% of rated current (101% of pk rating), <5 s auto recovery, >5 s recycle input to reset * 1.25% max -20 C to +50 C * Compensates for up to 0.3 V drop max if not required, sense teminals must be connected locally i.e +S to +M and -S to -M on CN1 * 12 V 3 mA applied between RCG & RC2 will inhibit the output of the unit and the fan
EMC & Safety
Emissions ESD Immunity Radiated Immunity EFT/Burst Surge Safety Approvals * EN55022, level B conducted EN55022, level A radiated * EN61000-4-2, level 2 contact, level 3 air * EN61000-4-3, level 3 * EN61000-4-4, level 3 * EN61000-4-5, level 3 line to line, level 4 line to ground * EN60950, UL60950, cUL (CSA 60950)
Temperature Coefficient Remote Sense
Remote On/Off
AC-DC
Models and Ratings
Input Voltage 3.3 V (2.64 - 3.96) 5.0 V (3.96 - 6.00) 7.5 V (5.25 - 8.25) 12 V (8.25 - 13.20) 15 V (10.50 - 16.50) 24 V (16.50 - 26.40) 36 V (25.20 - 39.60) 48 V (38.40 - 56.00) Notes Current Max 200 A 200 A 134 A 88 A 70 A 44 A 29 A 22 A Peak 51 A (1) Line 20 mV 20 mV 36 mV 48 mV 60 mV 96 mV 114 mV 192 mV Regulation Load 40 mV 40 mV 60 mV 100 mV 120 mV 150 mV 150 mV 300 mV Ripple & Noise(2) 120 mV 120 mV 150 mV 150 mV 150 mV 150 mV 200 mV 200 mV
CPB1K
Efficiency(3) 76% 81% 83% 84% 84% 86% 86% 86% Model Number CPB1KPS3V3 CPB1KPS05 CPB1KPS7V5 CPB1KPS12 CPB1KPS15 CPB1KPS24 CPB1KPS36 CPB1KPS48
1. Peak current duration 10 s max with duty cycle 35% 170-264 VAC only. 2. Measured over a 20 MHz bandwidth from 0 C to +50 C. 3. Measured at nominal 230 VAC input and 100% load.
Mechanical Details
M4 15.85 Name plate
13 9 ( 7.5)
Input terminal cover
25max
4-M4 Mounting Hole (Bottom sides)
20
10
104.75
AC(L) AC(N) FG( )
C N3 CN 2
79
CN3 CN2 CN1
Output terminal(+ ) 51.25
2.5
Output terminal(- )
( 24)
Output voltage adjustable potentiometer LED
29 (35)
165 0.5 240
6max 8-M4 Mounting Hole (Both sides)
380.5
Notes: 1. Tolerance: 1. 2. Weight: 2.2 Kg. 3. Dimensions in mm.
2-M4 2- 9
( 18) ( 25)
110 0.5 150
7 13
29
1650.5
11.5
Pin 1 2 3 4 5 6 7 8 9 10
CN1/CN2 PIN CONNECTIONS Function +M + Output Voltage Monitoring +S + Remote Sensing -M - Output Voltage Monitoring -S - Remote Sensing VB Voltage Balance CB Current Balance TRM Adjustment of Output Voltage - Remote Sensing -S RC2 Remote On/Off RCG Remote On/Off Ground
Peak Current Conditions:
Output Current (A)
61
Peak Current lp
(Peak Current)
Pin 1 2 3 4 5 6 7 8
CN3 PIN CONNECTIONS Function -S - Remote Sensing -S - Remote Sensing AUX Auxiliary Output (12V/0.1A) RC1 Remote On/Off AUXG AUX Ground N.C No Connection PG Power Good Signal PGG Power Good Ground
AC ( L) AC ( N) FG
H V .A D J C N1
AIR FLOW
* * * *
170-264 VAC t1 10 s lp Rated peak current lave Rated current t1 t1 + t2 x 100 [%] 35%
lave
(Average Current)
* Duty =
t1
t2
Mating Connector & Terminal - CN1, CN2 & CN3 Connector CN1 CN2 CN3 S10B-PHDSS S8B-PHDSS Mating Connector PHDR-10VS PHDR-8VS Terminal Reel SPHD-002T-P0.5 Loose BPHD-001T-P0.5 BPHD-002T-P0.5 Manufacturer J.S.T
AC-DC
Models and Ratings
Input Voltage 3.3 V (2.64 - 3.96) 5.0 V (3.96 - 6.00) 7.5 V (5.25 - 8.25) 12 V (8.25 - 13.20) 15 V (10.50 - 16.50) 24 V (16.50 - 26.40) 36 V (25.20 - 39.60) 48 V (38.40 - 56.00) Notes
1. At low input voltage i.e. 115 V nom derate to 65 A, 42 A and 32 A. 2. Peak current duration 10 s max with duty cycle 35% 170-264 VAC only.
CPB1K5
Regulation Peak 105 A (2) 70 A (2) Line 20 mV 20 mV 36 mV 48 mV 60 mV 96 mV 114 mV 192 mV Load 40 mV 40 mV 60 mV 100 mV 120 mV 150 mV 150 mV 300 mV Ripple & Noise(3) 120 mV 120 mV 150 mV 150 mV 150 mV 150 mV 200 mV 200 mV Efficiency(4) 75% 81% 81% 82% 86% 86% 86% 86% Model Number(3) CPB1K5PS3V3 CPB1K5PS05 CPB1K5PS7V5 CPB1K5PS12 CPB1K5PS15 CPB1K5PS24 CPB1K5PS36 CPB1K5PS48
Current Max 300 A 300 A 200 A 125 A 100 A 70 A (1) 47 A (1) 35 A
(1)
3. Measured over a 20 MHz bandwidth from 0 C to +50 C. 4. Measured at nominal 230 VAC input and 100% load.
Mechanical Details
( 7.5) 12.8 152.4 0.5
15.85
M4
Name plate
Input terminal cover
25max
8-M4 Mounting Hole (Both sides)
CN1 CN2 CN3
132
FG(
)
10
107
AC(L) AC(N) NC
13 9
Output voltage adjustable potentiometer
( 24)
LED Output terminal(-) Output terminal(+) 51.25
4
19 (45)
171.5 0.5 268 6max
Notes: 1. Tolerance: 1. 2. Weight: 3.4 Kg. 3. Dimensions in mm.
4-M4 2- 9
( 18) ( 25)
8-M4 Mounting Hole (Both sides) AIR FLOW
38 0.5 61
10 15
19
171.5 0.5
Output Current (A)
Pin 1 2 3 4 5 6 7 8 9 10
CN1/CN2 PIN CONNECTIONS Function +M + Output Voltage Monitoring +S + Remote Sensing -M - Output Voltage Monitoring -S - Remote Sensing VB Voltage Balance CB Current Balance TRM Adjustment of Output Voltage - Remote Sensing -S RC2 Remote On/Off RCG Remote On/Off Ground
Output Voltage Adjustment 60-110% of the rated output voltage is achieved by: 1. Using on-board potentiometer 2. Applying a voltage externally between TRM & -S on CN1 or CN2 3. Connecting a resistor externally between TRM & -S on CN1 or CN2 The external voltage level is calculated below and should not be less than -0.7 V or more than 3.0 V. Required Vout x 2.5 Vnom
Peak Current Conditions: * * * * 170-264 VAC t1 10 s lp Rated peak current lave Rated current t1 t1 + t2 x 100 [%] 35%
Peak Current lp
(Peak Current)
* Duty =
11.5
178
AC ( L) AC ( N) NC FG V.ADJ
Pin 1 2 3 4 5 6 7 8
CN3 PIN CONNECTIONS Function -S - Remote Sensing -S - Remote Sensing AUX Auxiliary Output (12V/0.1A) RC1 Remote On/Off AUXG AUX Ground N.C No Connection PG Power Good Signal PGG Power Good Ground
CN3
CN2
CN1
lave
(Average Current)
External Trim Voltage =
t1
t2
Mating Connector & Terminal - CN1, CN2 & CN3 Connector CN1 CN2 CN3 S10B-PHDSS S8B-PHDSS Mating Connector PHDR-10VS PHDR-8VS Terminal Reel SPHD-002T-P0.5 Loose BPHD-001T-P0.5 BPHD-002T-P0.5 Manufacturer J.S.T
04 AUG 05


▲Up To Search▲   

 
Price & Availability of CPB1KPS05

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X